Hybrid RES-based Stand Alone System


People Involved
F.A. Coutelieris, G.N. Prodromidis
Duration
01.09.2010 - 31.08.2012
Status
Finished
Budjet
2500€
Research Area
Modelling of Processes in Power Plants, RES-applications

Description:

A RES-based stand alone fully operational system was established to simulate several desirable loads . The equipment which was considered as essential during its installation is constituted by a polycrystalline Photovoltaic Panel by Sovello Company at 12 V and 205 W peak power, a Wind Turbine Air Breeze at 12 V and 300 W peak power and as a storage bank for the excess electricity from RES-technologies was used two Effecta batteries at 12 V and 55 Ah offered capacity, connected in-parallel. All these several technologies have been matched together with the embodiment of a Sunlight Lighting Charger/Controller at 12 V in combination with an Effekta inverter at 350 W peak offered power. Several different AC loads were also simulated through different combinations of 12 bulbs of several consumptions.